• A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller
  • A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller
  • A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller
  • A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller
  • A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller
  • A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller

A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller

After-sales Service: Have
Warranty: One Year
Structure: Axial Plunger Pump
Cylinder Number: Single Cylinder
Drive Mode: Hydraulic Driven Reciprocating Pump
Pump Shaft Position: Axial
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
A10VG45 A10VG28 A10VG63
Type
V Type
Power
Hydraulic
Straight Shaft Swashplate Piston Type
Pressureoil
Radial Plunger Pump Type
Axial Flow
Lead Time
in Stock
Usage
Paver
Colour
as Your Request
Size
53X34X45cm
Transport Package
in Wooden Box
Specification
0.1 CBM
Trademark
Rexroth
Origin
China
HS Code
8413503190
Production Capacity
100 Pieces

Product Description

Product Description

A10VG45 A10VG28 A10VG63 Rexroth Hydraulic Plunger Pump For Road Roller

Description

Closed circuit

Control devices: HD, HD3, HW, DG, DA1, DA2, EP3, EP4, EZ1, EZ2, etc.

Nominal pressure 4350 psi (300 bar); Peak pressure 5100 psi (350 bar)

Control device: MD, HD, HW, DG, DA, EP, EZ, etc.

 

The A10VG variable axial piston pump of swash plate design for hydrostatic closed circuit transmission

- Flow is proportional to drive speed and displacement and is infinitely variable

- Output flow increases with the swivel angle of the swash plate from 0 to its maximum value

- Flow direction changes smoothly when the swash plate is moved through the neutral position

- A wide range of highly adaptable control devices is available for different control and regulating functions

- The pump is equipped with two pressure-relief valves on the high pressure ports to protect the hydrostatic transmission (pump and motor) from overload

- The high-pressure relief valves also function as boost valves

- The integrated boost pump acts as a feed and control oil pump

- The maximum boost pressure is limited by a built-in boost pressure relief valve

 

Product Introduction:

Model: A10VG

Closed circuit

Control devices: HD, HD3, HW, DG, DA1, DA2, EP3, EP4, EZ1, EZ2, etc.

Nominal pressure 4350 psi (300 bar); Peak pressure 5100 psi (350 bar)

Control device: MD, HD, HW, DG, DA, EP, EZ, etc.

Detailed Photos

A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller

Product Parameters

Technical Data 

Table of values (theoretical values, without efficiency and tolerances; values rounded)

Size

A10VG18

A10VG28

A10VG45

A10VG63

Displacement  variable pump

Vg max

cm3

18

28

46

63

boost pump (at p = 20 bar)

Vg Sp

cm3

5.5

6.1

8.6

14.9

Speed  maximum at Vg max

Nmax

rpm

4000

3900

3300

3000

limited maximum 1)

nmax limited

rpm

4850

4200

3550

3250

intermittent maximum 2)

nmax interm.

rpm

5200

4500

3800

3500

minimum

nmin

rpm

500

500

500

500

Flow  at nmax continuous   and Vg max

qv max

l/min

72

109

152

189

Power 3) at nmax and Vg max

Δp = 300 bar

Pmax

kW

36

54.6

75.9

94.5

Torque 3) at Vg max

 

Δp = 300 bar

Tmax

Nm

86

134

220

301

Δp = 100 bar

T

Nm

28.6

44.6

73.2

100.3

Rotary stiffness

 

Shaft end S

c

Nm/rad

20284

32143

53404

78370

Shaft end T

c

Nm/rad

-

-

73804

92368

Moment of inertia for rotary group

JRG

kgm2

0.00093

0.0017

0.0033

0.0056

Angular acceleration, max. 4)

α

rad/s2

6800

5500

4000

3300

Filling capacity

V

L

0.45

0.64

0.75

1.1

Mass approx. (without through drive)

m

kg

14(18) 5)

25

27

39

Packaging & Shipping

Hydraulic fluid

Before starting project planning, please refer to our data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids) and RE 90223 (HF hydraulic fluids) for detailed information regarding the choice of hydraulic fluid and application conditions. The variable pump A10VG is unsuitable for operation with HFA, HFB and HFC. If HFD or environmentally acceptable hydraulic fluids are being used, the limitations regarding technical data and seals mentioned in RE 90221 and RE 90223 must be observed.

Details regarding the choice of hydraulic fluid

The correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature: in a closed circuit the circuit temperature. The hydraulic fluid should be chosen so that the operating viscosity in the operating temperature range is within the optimum range (νopt) - the shaded area of the selection diagram. We recommended that the higher viscosity class be selected in each case. Example: At an ambient temperature of X °C an operating temperature of 60 °C is set. In the optimum operating viscosity range (νopt; shaded area) this corresponds to the viscosity classes VG 46 or VG 68; to be selected: VG 68.

Please note: The case drain temperature, which is affected by pressure and speed, is always higher than the circuit temperature.

At no point in the system may the temperature be higher than 115 °C.

Shaft seal ring 

The service life of the shaft seal ring is affected by the speed of the pump and the case drain pressure. It is recommended that the average, continuous case drain pressure at operating temperature 3 bar absolute not be exceeded (max. permissible case drain pressure 6 bar absolute at reduced speed, see diagram). Short term (t < 0.1 s) pressure spikes of up to 10 bar absolute are permitted. The service life of the shaft seal ring decreases with an increase in the frequency of pressure spikes. The case pressure must be equal to or greater than the external pressure on the shaft seal ring.

Control unit, DG - Hydraulic Control, Direct Operated

With the Direct Operated Hydraulic Control (DG), pump displacement is controlled by a hydraulic control pressure applied

directly to the stroke cylinder through either the X1 or X2 port. In this way, the swash plate and thus the displacement is switchable from Vg = 0 to Vg max. Each direction of through put flow is assigned to a port.

MD - Mechanical Pivot Control (Size 18 only) 

The swash plate is adjusted directly and thus the displacement of the pump is continuously varied depending on the position of the pivot. A swivel direction of the pivot is assigned to each flow direction.

HD - Hydraulic Control, Pilot-Pressure Related

Depending on the pressure difference of the pilot pressure pSt in the two control lines (ports Y1 and Y2), the stroke cylinder of the pump is supplied with control pressure via the HD control unit. Thus the swash plate - and therefore, the displacement - to be infinitely adjustable. A different through put flow direction is associated with each control line. If the pump is also equipped with a DA control valve, automotive operation is possible for travel drives.

HW - Hydraulic Control, Mechanical Servo

Depending on the actuation direction a or b of the control lever, the stroke cylinder of the pump is supplied with control

pressure via the HW control unit. Thus, the swash plate - and, therefore, the displacement - to be infinitely adjustable. A different through put flow direction is associated with each direction of control lever actuation.

DA - Hydraulic Control, Speed Related

The DA control is an engine speed-dependent, or automotive, type control system. The built-in DA regulating cartridge generates

a pilot pressure that is proportional to pump (engine) drive speed. This pilot pressure is directed to the positioning cylinder of the pump by a solenoid actuated 4/3 way directional valve. Pump displacement is infinitely variable in each direction of flow, and is influenced by both pump drive speed and discharge pressure. Flow direction (i.e. machine forward or reverse) is controlled by energizing solenoid a or b. Increasing pump drive speed generates a higher pilot pressure from the DA cartridge, with a subsequent increase in pump flow and/or pressure. Dependent on the selected pump operating characteristics, increasing system pressure (i.e. machine load) causes the pump to swivel back towards a smaller displacement. Engine overload (anti-stall) protection is achieved by the combination of this pressure-related pump de-stroking, and the reduction of pilot pressure as the engine speed drops. Any additional power requirement, such as implement hydraulics, may result in further engine pull down. This causes a further reduction in pilot pressure and therefore pump displacement. Automatic power division and full utilization of available power is thus achieved for both the vehicle transmission and the implement hydraulics, with priority given to the implement hydraulics. To provide controllable reduced vehicle speed operation when high engine speeds are required for fast implement hydraulics, various inching options are available. The DA regulating cartridge can also be used in pumps with conventional control devices, such as EP, HW or HD, to provide an engine anti-stall function, or as a combination of automotive and displacement control functions.

EP - Electric Control, With Proportional Solenoid

Depending on the preselected current I at the two proportional solenoids (a and b), the stroke cylinder of the pump is supplied with control pressure via the EP control unit. Thus the swash plate and therefore the displacement to be infinitely adjustable. One direction of through put flow is assigned to each proportional solenoid.

EZ - Electric Two-Position Control, With Switching Solenoid

By energizing or de-energizing a control current to either switching solenoid a or b, the stroke cylinders of the pump are supplied with control pressure by the EZ control unit. In this way, the swash plate and thus the displacement is switchable without intermediate settings from Vg = 0 to Vg max. Each direction of through put flow is assigned to a switching solenoid.

A10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road RollerA10vg45 A10vg28 A10vg63 Rexroth Hydraulic Plunger Pump for Road Roller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
101~500 square meters